^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 1) # SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 2) %YAML 1.2
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 3) ---
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 4) $id: http://devicetree.org/schemas/ptp/ptp-idt82p33.yaml#
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 5) $schema: http://devicetree.org/meta-schemas/core.yaml#
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 6)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 7) title: IDT 82P33 PTP Clock Device Tree Bindings
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 8)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 9) description: |
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 10) IDT 82P33XXX Synchronization Management Unit (SMU) based PTP clock
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 11)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 12) maintainers:
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 13) - Min Li <min.li.xe@renesas.com>
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 14)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 15) properties:
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 16) compatible:
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 17) enum:
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 18) - idt,82p33810
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 19) - idt,82p33813
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 20) - idt,82p33814
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 21) - idt,82p33831
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 22) - idt,82p33910
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 23) - idt,82p33913
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 24) - idt,82p33914
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 25) - idt,82p33931
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 26)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 27) reg:
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 28) maxItems: 1
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 29)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 30) required:
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 31) - compatible
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 32) - reg
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 33)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 34) additionalProperties: false
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 35)
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 36) examples:
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 37) - |
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 38) i2c {
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 39) #address-cells = <1>;
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 40) #size-cells = <0>;
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 41) phc@51 {
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 42) compatible = "idt,82p33810";
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 43) reg = <0x51>;
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 44) };
^8f3ce5b39 (kx 2023-10-28 12:00:06 +0300 45) };